Pyroxylin Plastic Chemical Storage Specifications

Compliant storage and rental solutions for Pyroxylin Plastic (C12H16N4O18). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Pyroxylin Plastic

It is used in lacquers, plastics, and artificial leathers. Pyroxylin lacquers are made by dissolving pyroxylin in a mixture of volatile solvents and adding a plasticizer and a pigment or dye.

Structured hazard data

Hazard class
See SDS
Storage category
Flammable Storage
Flammable
Yes
Flash point
Closed cup: 4.44°C (40°F)
Storage temperature
See SDS
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Reactive or incompatible with the following materials: oxidizing materials

FLAMMABLE SOLIDS - Category 2

Fire Suppression System

Dry Chemical fire suppression is recommended for Pyroxylin Plastic

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Pyroxylin Plastic (C12H16N4O18). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Use dry chemical, CO₂, water spray (fog) or foam.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Pyroxylin Plastic should account for its listed hazards, climate control needs, and segregation requirements. Reactive or incompatible with the following materials: oxidizing materials

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Physical state Melting point Vapor pressure Relative density Vapor density Solubility Solid. Not available. 1.66 Not available. 0 kPa (0 mm Hg) [room temperature] Partially soluble in the following materials: methanol, diethyl ether and acetone. Insoluble in the following materials: cold water and hot water. Odor Odorless. pH Color White. Evaporation rate Not available. Auto-ignition temperature Flash point >160°C (>320°F) Closed cup: 4.44°C (40°F) Not available. Not applicable. Viscosity Dynamic (room temperature): Not applicable. Kinematic (room temperature): Not applicable. Odor threshold Not available. Partition coefficient: n-octanol/ water Appearance Boiling point Not available. Flammability (solid, gas) Product becomes a 'Flammable Solid category 2' after removing the membrane from the package. If the product is still in it's original packaging it is not a 'Flammable Solid category 2'. Lower and upper explosive (flammable) limits Not available. Burning rate Not available. Burning time Not availa

Matched to this chemical

Recommended storage solutions for Pyroxylin Plastic

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Pyroxylin Plastic be stored?

Store Pyroxylin Plastic in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: Follow the temperature range listed on the manufacturer SDS.. Compatibility notes: Reactive or incompatible with the following materials: oxidizing materials US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Pyroxylin Plastic flammable?

Yes — Pyroxylin Plastic is flagged as a flammable hazard in this database (Yes). Flash point: Closed cup: 4.44°C (40°F) . Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Pyroxylin Plastic?

Pyroxylin Plastic is listed as: Consult the SDS and applicable hazard classification. FLAMMABLE SOLIDS - Category 2

What fire suppression is recommended for Pyroxylin Plastic?

Dry Chemical fire suppression is generally recommended for Pyroxylin Plastic (C12H16N4O18). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Pyroxylin Plastic storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Pyroxylin Plastic. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.